<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-24 16-01-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 69 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.7 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 64 kHz 19040 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 5,68 dBr 7,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 64 kHz MIN: 8 kHz % above 76 kHz: 0,0000 Acquired: 2025/03/24 16.00.19 Total samples: 19040 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000 6000
FM Scope MAX: 7,0 dBr MIN: 3,9 dBr AVE: 5,68 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2025/03/24 16.00.19) 15.46 15.48 15.50 15.52 15.54 15.56 15.58 16.00 0 2 4 6 8 Pm [dBr]